Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Iguchi, Tetsuo; Watanabe, Kenichi*; *; Nose, Shoichi; Harano, Hideki;
JNC TY9400 2000-019, 34 Pages, 2000/05
None
Isozaki, Kazunori; ; Ito, Hideaki; ; Chatani, Keiji; ;
PNC TN9520 93-006, 198 Pages, 1992/11
None
Morimoto, Makoto; Okubo, Toshiyuki; ; ; ; ;
PNC TN9410 91-334, 64 Pages, 1991/10
An failed fuel detection and location system (FFDL) using a sipping method is adopted as the FFDL of Joyo. FFDL has not operated since the first falled fuel simulated (FFDL-I) test in April, 1985 because Joyo has not yet experienced any operation with breached fuels. Therefore, the operational test (II) of FFDL was carried out on July 1219, 1991 for a preparation of the FFDL-II test which is scheduled in 1992. Main results from the test are as follows ; (1)The adequacy of the functions and operating procedure of FFDL was reaffirmed and the operating experience was gained. (2)Radioactivity measurement was conducted by FFDL for six subassemblies and their integrity was confirmed.
Kato, Shinya; Morohashi, Yuko; Muto, Keitaro
no journal, ,
In order to confirm performance of MONJU failed fuel detection and location system (FFDL), confirmation of accuracy for identifying failed fuel will be conducted by using simulated tag gas.
Morohashi, Yuko; Higuchi, Tetsuo*; Ishii, Keisuke*; Kitamura, Akihiro*
no journal, ,
no abstracts in English